The normal probe with one of several two goal disks plus a replaceable chisel wear cap helps make the Magna-Mike 8600 gauge Preferably fitted to most automotive tear seam apps exactly where measurements have to be manufactured in a thin channel or groove.

It’s also superior follow to help keep a reference common of recognised thickness close by that is similar in thickness for the pieces you’re measuring. Using this method, you are able to periodically Verify the thickness of a reference conventional to confirm which the instrument continues to be measuring inside specifications.

The Magna-Mike® has an intensive file-based mostly alphanumeric details logger that may be meant to easily retailer and transfer thickness readings.

Website page 102 The models and determination on the differential thickness are the same as All those chosen for the thickness measurement. Once you press [Help save] while in differential modes, the Magna-Mike 8600 saves the two the Stay and differential measurement values. The person can pick out to Screen the differential price or the Are living thickness measurement in big font. Website page 103: Utilizing the Bare minimum/Most Thickness Method

In case the exam product is quite thick, or calls for fantastic accuracy, the operator can decide to complete a guide Q-CAL before Each and every new measurement. Once the Magna-Mike 8600 probe is getting used hand-held to scan significant objects, rather than while in the probe stand, It's going to be required to accomplish a guide Q-CAL in the event the orientation of your probe improvements.

This video describes ways to use the EPOCH 650 ultrasonic flaw detector to discover discontinuities as well as other flaws in rails.

The Magna-Mike™ 8600 Hall-effect thickness gauge works by using a straightforward magnetic method to generate trustworthy and repeatable measurements on plastic bottles, packaging, along with other nonferrous components.

When scanning the probe along the floor or significant corners, the compact metal focus on ball will abide by. Inside the Minimal Mode feature, the gauge frequently displays each the particular thickness and the bottom thickness looking at.

The don idea should really only be hand tightened. Employing tools to tighten the put on idea can completely destruction the probe. Do not make use of the Magna-Mike 8600 probe without a don idea. Doing so will result in inaccurate measurements and may cause long-lasting harm to the probe. Website page seventy eight: Common Goal Balls

Vanta handheld XRF analyzers for PMI deliver hugely certain material chemistry to speedily and correctly identify alloy grades to aid make sure right alloy set up in crucial spots.

This guide includes crucial info on how you can use this Olympus merchandise properly and proficiently.

The Magna-Mike is actually a Corridor Impact thickness gage that takes advantage of a magnetic probe to execute precise measurements on nonferrous and thin components for example plastic bottles.

When the probe is replaced, dropped, or contacts hugely-magnetic Olympus Magna-Mike 8600 Thickness Gauge product Notice In case the Magna-Mike 8600 has just been turned on, or if a probe has just been connected, enable the gage to heat up for at least 5 minutes While using the probe connected just before executing a calibration. Website page 86: Table 9 Calibration Precision To the 86Pr-three Probe

The ball/concentrate on sizing indicator shows for which ball/target dimensions the instrument is at present calibrated. The Magna-Mike 8600 also shows a wear tip indicator: a white dot or even a white triangle.